Catalog pricing shown. Please Sign In to see your pricing.

Arcoaire HP Single Phase Split System Deluxe Single Stg 2 Ton 30k BTU AHU 15.2 SEER2

Arcoaire HP Single Phase Split System Deluxe Single Stg 2 Ton 30k BTU AHU 15.2 SEER2
Kit Includes Whip 6' 1/2" 10GA, No Vent Caps, 2" Plastic Pad, 2H/2C Thermostat, 50' Line Set 1/2" Insul, PVC Adapters/Fittings, 6" Heat Pump Riser, Furnace Leveler, PVC Ptrap Kit, Disconnect

This retail set contains

Vendor Name:
Arcoaire
URI Part Number:
Arcoaire HP Single Phase Split System Deluxe Single Stg 2 Ton 30k BTU AHU 15.2 SEER2
Shipping Weight (Lbs.):
200
Energy Star:
Energy Star 6.1 Compliant: 15.2 SEER2, 11.7 EER2, 7.8 HSPF2
Includes:
H4H5S24AKAAA, FJMA4X30L0BB, HPKIT4
Nominal Capacity (BTUH):
24000
Cooling Efficiency (EER2):
12.5
Cooling Efficiency (SEER2):
15.2
Heating Efficiency HSPF2:
7.8 HSPF2
System Indoor Type:
AHU
System Outdoor Type:
Single Stage
System Coil Configuration:
Multi Position
System AHU Type:
Standard
System Nominal Tons:
2.0 Ton
AHRI System Number:
210998784
Heat Pump, Single Phase, Split AHU Single Stage, Multi Position H4H5S/FJMA4

Heat Pump
  • Scroll Compressors on all models
  • Welded Aluminum Tube / Aluminum Fin Coil
  • Improved Efficiency w/ Multi Directional Internal Enhancements
  • Less Sensitivity to Pressure Drop
  • Heat Shrink Wrap Protects Copper / Aluminum Joints
  • AL/AL w/ Zinc Cladding Provides Enhanced Corrosion Protection
  • Approximately 50% Lighter than Copper Coils
  • Bi Flow Filter Drier Supplied for Field Installation
  • Suction Line Accumulator Standard
  • Self Configuring Operation & Text Based Diagnostics w/ Ion Control
  • Compressor Sound Blanket & Isolation Grommets Factory Installed
  • Extended Service Valve to Accommodate Press Fittings
  • High & Low Pressure Switches
  • Outdoor Temp Sensor Factory Installed
  • Factory Charged w/ R410A Refrigerant
  • Long Line Set Capability (refer to spec sheet for details)
  • Low Ambient Cooling Capable w/ Optional Kit
  • Galvanized Steel Cabinet w/ High Gloss, Baked on Powder Coat Paint
  • Corner Posts for Added Cabinet Strength
  • Coated Hail Guard Coil Protection
  • Post Painted (black) Coil
  • Coated Cabinet Screws
  • Reliable Time / Temperature Defrost Control
  • Internal Pressure Relief Valve & Internal Thermal Overload

Multi Position Fan Coil

  • Factory installed TXV metering device
  • High efficiency EC 5-speed motor
  • Time delay relay (TDR)
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • Multi position installation (Horizontal kit required 30-60)
  • Field convertible to down flow with accessory kit
  • Primary and secondary drain fittings with brass inserts
  • Thick insulation with R value of 4.2 w/ vapor barrier
  • Field installed heater packages from 5 kW - 30 kW available